VDE pliers with moulded handle insulation
GEDORE pliers for gripping, cutting and stripping
GEDORE VDE insulated pliers with protective handle insulation are designed for gripping, cutting and stripping work on electrical installations. The range includes flat nose, round nose and long nose pliers, wire stripping pliers, combination pliers and side cutters. Heavy-duty side cutters and high-leverage combination pliers offer the advantage of up to 35% less effort when cutting. Depending on the version, the stripping pliers cover conductor cross-sections from 0.5 to 6.0 mm², while angled long nose pliers are particularly suitable for working in difficult-to-reach areas.
VDE pliers with GEDORE Check-Tool insulation: GEDORE VDE dip-insulated pliers


GEDORE VDE 8098-160 H VDE Insulation Stripping Pliers with Sheath Insulation 160 mm Opens automatically, with spring and adjusting screw, V-shaped cutting jaws for stripping single and multi-wire conductors with plastic insulation, Easy adjustment to the required wire or strand diameter by means of the set screw and lock nut, For wires from 0.8 to 6.0 mm², GEDORE special hardened and tempered steel, drop-forged, oil-hardened and annealed, Legs VDE insulated up to 1000 V, in accordance with DIN EN IEC 60900, cover insulation .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€33.24*

€62.14*
incl. VAT
VDE 8099-160 H VDE Insulation Stripping Pliers STRIP-FIX with Sheath Insulation 160 mm GEDORE VDE 8099-160 H VDE Insulation Stripping Pliers STRIP-FIX with Sheath Insulation 160 mm Self-adjusting, for wires 0.5 - 5.0 mm², V-shaped cutting jaws for stripping single and multi-wire conductors with plastic insulation, GEDORE special hardened and tempered steel, drop-forged, oil-hardened and annealed, Handles with VDE insulating sleeves up to 1000 V, acc. to EN 60900/IEC 60900 .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€62.14*

2
Variants
From €50.59*

GEDORE VDE 8315-160 H VDE Insulation Stripping Side Cutter 160 mm Double-function electricians’ side cutters: for cutting and stripping wire, Stripping holes for solid and stranded conductors with 1.5 mm² and 2.5 mm² conductor cross-section, Induction-hardened precision cutting edges, hardness 61 - 63 HRC, GEDORE special hardened and tempered steel, drop-forged, oil-hardened and annealed, Handles with VDE insulating sleeves up to 1000 V, acc. to EN 60900/IEC 60900 .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€43.55*

GEDORE VDE 8314-180 H VDE Heavy Duty Side Cutter with Sheath Insulation 180 mm With slender head, ideal for confined spaces, Induction-hardened precision cutting edges, hardness 63 - 65 HRC, GEDORE special hardened and tempered steel, chrome-plated, Handles with VDE insulating sleeves up to 1000 V, acc. to EN 60900/IEC 60900 .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€37.83*

2
Variants

2
Variants
From €43.55*

2
Variants
From €35.58*

3
Variants
From €29.85*

4
Variants
From €34.41*

GEDORE VDE 8120-160 H VDE Flat Pliers with Sheath Insulation 160 mm With long jaws, serrated gripping faces, GEDORE special hardened and tempered steel, chrome-plated, Handles with VDE insulating sleeves up to 1000 V, acc. to EN 60900/IEC 60900 .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€29.85*

GEDORE VDE 8122-160 H VDE Round Nose Pliers with Sheath Insulation 160 mm With long jaws, serrated gripping faces, For gripping and bending, GEDORE special hardened and tempered steel, drop-forged, oil-hardened and annealed, Handles with VDE insulating sleeves up to 1000 V, acc. to EN 60900/IEC 60900 .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€29.85*

GEDORE VDE S 8003 H VDE Pliers Set with Sheath Insulation 3 -piece Practical set composition in environmentally-friendly cardboard box, Handles with VDE insulating sleeves up to 1000 V, acc. to EN 60900/IEC 60900 Components VDE 8250-180 H VDE combo pliers sleeve ins. 180mm - GED1550950 VDE 8132-160 H VDE flat pliers sleeve ins. 160mm - GED1552112 VDE 8314-160 H VDE Side cutter with VDE insulating sleeves 160 mm - GED1552163
€87.30*

GEDORE 1102-002 VDE VDE Pliers Set 3 -piece in L-BOXX Mini Practical set composition, Handles with VDE insulating sleeves up to 1000 V, acc. to EN 60900/IEC 60900, In GEDORE L-BOXX® Mini, incl. divider set Features Dimensions: W 260 x D 155 x H 63 mm Components VDE 8132-160 H VDE flat pliers sleeve ins. 160mm - GED1552112 VDE 8250-180 H VDE combo pliers sleeve ins. 180mm - GED1550950 VDE 8314-160 H VDE Side cutter with VDE insulating sleeves 160 mm - GED1552163 1102 L GEDORE L-BOXX Mini - GED2950529 EI-1102 Egg-crate foam 235x140x35mm - 2951002
€87.39*

GEDORE 1102-004 VDE VDE Pliers Set 3 -piece in L-BOXX Mini Practical set composition, Handles with VDE insulating sleeves up to 1000 V, acc. to EN 60900/IEC 60900, In GEDORE L-BOXX® Mini, incl. divider set Features Dimensions: W 260 x D 155 x H 63 mm Components VDE 8098-160 H VDE Wire stripper with VDE insulating sleeves 160 mm - GED1552074 VDE 8250-180 H VDE combo pliers sleeve ins. 180mm - GED1550950 VDE 8314-160 H VDE Side cutter with VDE insulating sleeves 160 mm - GED1552163 1102 L GEDORE L-BOXX Mini - GED2950529 EI-1102 Egg-crate foam 235x140x35mm - 2951002
€112.60*

GEDORE VDE 8092-160 H VDE Cable Scissors For cutting multi-core copper and aluminium cables up to max. 50 mm² or up to a Ø of 10 mm, Legs VDE insulated up to 1000 V, in accordance with DIN EN IEC 60900, cover insulation, Precision ground for optimum action, new cutting-edge geometry, Not suitable for steel wire and hard-drawn copper conductors, Hardness 55 HRC, Special hardened and tempered steel, forged and ground .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€37.03*

GEDORE R29400180 VDE Side Cutter 180mm 2K Handle Acc. to DIN ISO 5749, Complies with VDE 0682 Part 201 and EN/IEC 60900, High cutting performance with low force, Slim head, Induction-hardened long cutting edges, 2-component-handle for a hands-friendly transfer of force, Special tool steel, forged .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€25.09*

GEDORE R29510200 VDE Flat Nose Pliers 200mm 45° 2K Handle Acc. to DIN ISO 5746, Complies with VDE 0682 Part 201 and EN/IEC 60900, 45° angled grip surfaces, lengthways-serrated, Induction-hardened long cutting edges, 2-component-handle for a hands-friendly transfer of force, Special tool steel, forged .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€26.17*

GEDORE R29500200 VDE Flat Nose Pliers 200mm 2K Handle Acc. to DIN ISO 5745, Complies with VDE 0682 Part 201 and EN/IEC 60900, Straight grip surfaces, lengthways-serrated, Induction-hardened long cutting edges, 2-component-handle for a hands-friendly transfer of force, Special tool steel, forged .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€24.99*

GEDORE R29100010 VDE Water Pump Pliers 10 Inches 7-fold adjustable Acc. to DIN ISO 8976 Form C, Complies with VDE 0682 Part 201 and EN/IEC 60900, Lengthways-serrated grip surfaces, Lengthways-serrated grip surfaces, Head and knuckle brightly ground, Chrome-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€33.13*






















