VDE S 8003 VDE Pliers Set with Dip Insulation 3 -piece




















€112.60 *
Delivery time: approx. 1-3 working days
| Article name | VDE S 8003 VDE Pliers Set with Dip Insulation 3 -piece |
|---|---|
| Product number: | GED6708120 |
| Manufacturer | GEDORE |
| 1000 V insulated | Yes |
| Contents (Qty of pieces) | 3 |
| Customs tariff number | 82032000 |
| Design non-sparking | No |
| Net weight | 0,76 kg |
| Parts list (Text) | VDE 8132-160, VDE 8250-180, VDE 8314-160 |
| Reach | compliant |
| Standard | EN 60900/IEC60900, DIN ISO 5746, DIN ISO 5745, DIN ISO 5749 |
| Total height | 30 mm |
| Total length | 315 mm |
| Total width | 156 mm |
| VDE certified | Yes |
GEDORE VDE S 8003 VDE Pliers Set with Dip Insulation 3 -piece
Practical set composition in environmentally-friendly cardboard box, Handles with VDE dipped insulation up to 1000 V, acc. to EN 60900/IEC 60900, two-ply Check-Tool insulation
Components
Spare parts

Variants from€40.26*
incl. VAT
VDE 8250-180 VDE Heavy Duty Combination Pliers with Dip Insulation 180 mm Variante: GED_GRP_3012_GED6720090
GEDORE VDE 8250-180 VDE Heavy Duty Combination Pliers with Dip Insulation 180 mm Individually tested, For heavy continuous use, Good lever action for easy cutting, For round and flat material, Extra long blades, Induction-hardened precision cutting edges, hardness 62 - 64 HRC, For all wire types including piano wire, 1.6 mm, Serrated gripping faces, Inserted joint, High cutting performance with guaranteed 35% less effort, Handles with VDE dipped insulation up to 1000 V, acc. to EN 60900/IEC 60900, two-ply Check-Tool insulation, GEDORE special hardened and tempered steel, drop-forged, oil-hardened and annealed, chrome-plated .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body GEDORE VDE Heavy Duty Combination Pliers with Dip Insulation 180 mm with Check-Tool insulation All GEDORE VDE safety tools with soft-plastic insulation feature Check-Tool insulation The two-colour, multi-layer insulation is red on the outside and yellow on the inside and supports visual safety inspection The tool GEDORE VDE 8250-180 must be free from visible damage. If the yellow inner layer becomes visible, the tool must be taken out of service and disposed of What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€40.26*

Variante: GED_GRP_2996_GED6721570
GEDORE VDE 8132-160 VDE Flat Nose Pliers with Dip Insulation 160 mm Long, flat-round jaws, straight gripping faces, serrated, For holding, gripping, bending and cutting, Induction-hardened precision cutting edges, hardness 61 - 63 HRC, GEDORE special hardened and tempered steel, drop-forged, oil-hardened and annealed, Handles with VDE dipped insulation up to 1000 V, acc. to EN 60900/IEC 60900, two-ply Check-Tool insulation .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body GEDORE VDE Flat Nose Pliers with Dip Insulation 160 mm with Check-Tool insulation All GEDORE VDE safety tools with soft-plastic insulation feature Check-Tool insulation The two-colour, multi-layer insulation is red on the outside and yellow on the inside and supports visual safety inspection The tool GEDORE VDE 8132-160 must be free from visible damage. If the yellow inner layer becomes visible, the tool must be taken out of service and disposed of What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€41.32*

Variante: GED_GRP_3042_GED6743620
GEDORE VDE 8314-160 VDE Side Cutter with Sheath Insulation 60 mm Acc. to DIN ISO 5749, With slender head, ideal for confined spaces, Induction-hardened precision cutting edges, hardness 63 - 65 HRC, GEDORE special hardened and tempered steel, chrome-plated, Handles with VDE dipped insulation up to 1000 V, acc. to EN 60900/IEC 60900, two-ply Check-Tool insulation .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body GEDORE VDE Side Cutter with Sheath Insulation 60 mm with Check-Tool insulation All GEDORE VDE safety tools with soft-plastic insulation feature Check-Tool insulation The two-colour, multi-layer insulation is red on the outside and yellow on the inside and supports visual safety inspection The tool GEDORE VDE 8314-160 must be free from visible damage. If the yellow inner layer becomes visible, the tool must be taken out of service and disposed of What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€37.83*
Information on product safety
Manufacturer:
GEDORE Werkzeugfabrik GmbH & Co. KG Remscheider Str. 149, 42899 Remscheid, Germany +49 2191 596 0 [email protected]
Spare parts

Variants from€40.26*
incl. VAT
VDE 8250-180 VDE Heavy Duty Combination Pliers with Dip Insulation 180 mm Variante: GED_GRP_3012_GED6720090
GEDORE VDE 8250-180 VDE Heavy Duty Combination Pliers with Dip Insulation 180 mm Individually tested, For heavy continuous use, Good lever action for easy cutting, For round and flat material, Extra long blades, Induction-hardened precision cutting edges, hardness 62 - 64 HRC, For all wire types including piano wire, 1.6 mm, Serrated gripping faces, Inserted joint, High cutting performance with guaranteed 35% less effort, Handles with VDE dipped insulation up to 1000 V, acc. to EN 60900/IEC 60900, two-ply Check-Tool insulation, GEDORE special hardened and tempered steel, drop-forged, oil-hardened and annealed, chrome-plated .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body GEDORE VDE Heavy Duty Combination Pliers with Dip Insulation 180 mm with Check-Tool insulation All GEDORE VDE safety tools with soft-plastic insulation feature Check-Tool insulation The two-colour, multi-layer insulation is red on the outside and yellow on the inside and supports visual safety inspection The tool GEDORE VDE 8250-180 must be free from visible damage. If the yellow inner layer becomes visible, the tool must be taken out of service and disposed of What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€40.26*

Variante: GED_GRP_2996_GED6721570
GEDORE VDE 8132-160 VDE Flat Nose Pliers with Dip Insulation 160 mm Long, flat-round jaws, straight gripping faces, serrated, For holding, gripping, bending and cutting, Induction-hardened precision cutting edges, hardness 61 - 63 HRC, GEDORE special hardened and tempered steel, drop-forged, oil-hardened and annealed, Handles with VDE dipped insulation up to 1000 V, acc. to EN 60900/IEC 60900, two-ply Check-Tool insulation .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body GEDORE VDE Flat Nose Pliers with Dip Insulation 160 mm with Check-Tool insulation All GEDORE VDE safety tools with soft-plastic insulation feature Check-Tool insulation The two-colour, multi-layer insulation is red on the outside and yellow on the inside and supports visual safety inspection The tool GEDORE VDE 8132-160 must be free from visible damage. If the yellow inner layer becomes visible, the tool must be taken out of service and disposed of What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€41.32*

Variante: GED_GRP_3042_GED6743620
GEDORE VDE 8314-160 VDE Side Cutter with Sheath Insulation 60 mm Acc. to DIN ISO 5749, With slender head, ideal for confined spaces, Induction-hardened precision cutting edges, hardness 63 - 65 HRC, GEDORE special hardened and tempered steel, chrome-plated, Handles with VDE dipped insulation up to 1000 V, acc. to EN 60900/IEC 60900, two-ply Check-Tool insulation .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body GEDORE VDE Side Cutter with Sheath Insulation 60 mm with Check-Tool insulation All GEDORE VDE safety tools with soft-plastic insulation feature Check-Tool insulation The two-colour, multi-layer insulation is red on the outside and yellow on the inside and supports visual safety inspection The tool GEDORE VDE 8314-160 must be free from visible damage. If the yellow inner layer becomes visible, the tool must be taken out of service and disposed of What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
€37.83*