1500 CT1-VDE 2170 PZ VDE Screwdriver in Check-Tool-Modul
















€102.24 *
Delivery time: approx. 1-3 working days
| Article name | 1500 CT1-VDE 2170 PZ VDE Screwdriver in Check-Tool-Modul |
|---|---|
| Product number: | GED2309173 |
| Manufacturer | GEDORE |
| 1000 V insulated | No |
| Contents (Qty of pieces) | 6 |
| Customs tariff number | 82054000 |
| Material | Foam |
| Net weight | 0,625 kg |
| Parts list (Text) | VDE Screwdriver Slot No. VDE 2170, SW 4 5.5 6.5 8 mm, VDE Screwdriver Phillips No. VDE 2160 PZ 1 2 |
| Reach | compliant |
| Storage | 1/3 Check-Tool-Module |
| Total height | 35 mm |
| Total length | 310 mm |
| Total width | 158 mm |
| VDE certified | No |
GEDORE 1500 CT1-VDE 2170 PZ VDE Screwdriver in Check-Tool-Modul
Components
- VDE 2170 4 VDE Screwdriver 4 mm - GED1612255
- VDE 2170 5,5 VDE Screwdriver 5.5 mm - GED1612271
- VDE 2170 6,5 VDE Screwdriver 6.5 mm - GED1612298
- VDE 2170 8 VDE Screwdriver 8 mm - GED1612301
- VDE 2160 PZ 1 VDE-Screwdriver Cross Recess PZ 1 - GED1612182
- VDE 2160 PZ 2 VDE-Screwdriver Cross Recess PZ 2 - GED1612190
- EI-1500 CT1-VDE 2170 Check-Tool-Module empty - GED2322552
Spare parts

Variante: GED_GRP_2047_GED1612255
GEDORE VDE 2170 4 VDE Screwdriver Flat 4 mm Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 2380-1 Form A, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€7.09*

Variante: GED_GRP_2047_GED1612271
GEDORE VDE 2170 5,5 VDE Screwdriver Flat 5,5 mm Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 2380-1 Form A, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€7.09*

Variante: GED_GRP_2047_GED1612298
GEDORE VDE 2170 6,5 VDE Screwdriver Flat 6,5 mm Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 2380-1 Form A, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€7.09*

Variante: GED_GRP_2047_GED1612301
GEDORE VDE 2170 8 VDE Screwdriver Flat 8 mm Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 2380-1 Form A, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€7.09*

Variante: GED_GRP_2038_GED1612182
GEDORE VDE 2160 PZ 1 VDE Screwdriver Cross Slot PZ 1 Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 8764-1 PZ, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€8.25*

Variante: GED_GRP_2038_GED1612190
GEDORE VDE 2160 PZ 2 VDE Screwdriver Cross Slot PZ 2 Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 8764-1 PZ, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€8.25*

Variante: GED_GRP_2536_GED2322552
GEDORE EI-1500 CT1-VDE 2170 Check-tool module, empty Simple optical completeness check due to 2-coloured foam inserts, Particularly suitable for work in sensitive areas, where it must be ensured that no tools are left behind, Base layer blue, top layer black. The color blue indicates missing tools, The tool lies slip-proof in its nest and is protected against damage, Recessed grips facilitate the removal of the tool, Clearly visible tool contours make it easier to put the tool back into the correct nest, Resistant against oils and grease, Easy to clean with water, soap and a hand/nail brush, Dimensions: W 157.5 x D 310 mm
Variants from€30.93*
Information on product safety
Manufacturer:
GEDORE Werkzeugfabrik GmbH & Co. KG Remscheider Str. 149, 42899 Remscheid, Germany +49 2191 596 0 [email protected]
Spare parts

Variante: GED_GRP_2047_GED1612255
GEDORE VDE 2170 4 VDE Screwdriver Flat 4 mm Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 2380-1 Form A, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€7.09*

Variante: GED_GRP_2047_GED1612271
GEDORE VDE 2170 5,5 VDE Screwdriver Flat 5,5 mm Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 2380-1 Form A, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€7.09*

Variante: GED_GRP_2047_GED1612298
GEDORE VDE 2170 6,5 VDE Screwdriver Flat 6,5 mm Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 2380-1 Form A, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€7.09*

Variante: GED_GRP_2047_GED1612301
GEDORE VDE 2170 8 VDE Screwdriver Flat 8 mm Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 2380-1 Form A, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€7.09*

Variante: GED_GRP_2038_GED1612182
GEDORE VDE 2160 PZ 1 VDE Screwdriver Cross Slot PZ 1 Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 8764-1 PZ, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€8.25*

Variante: GED_GRP_2038_GED1612190
GEDORE VDE 2160 PZ 2 VDE Screwdriver Cross Slot PZ 2 Individually tested, VDE insulation up to 1000 V, acc. to EN 60900/IEC 60900, fully insulated blade, Tip as per DIN ISO 8764-1 PZ, 3-component Power-Grip³ handle with suspension hole, Ergonomic handle shape for accurate, non-tiring work, Positive connection of handle and blade for optimum power transmission, Type of drive marked at the end of the handle, Blade of galvanised molybdenum-vanadium steel .vde-info {margin-top: 30px;} .vde-info-row {display: flex; align-items: flex-start; gap: 5mm; margin-bottom: 20px;} .vde-info-icon {display: block; width: 75px; height: 75px; flex: 0 0 75px; object-fit: contain;} .vde-info-list {margin: 0; padding-left: 20px;} The double-triangle symbol indicates that the tool has been individually tested Individually tested at 10,000 V AC (alternating voltage) based on EN 60900/IEC 60900 Insulated up to 1,000 V in accordance with EN 60900/IEC 60900 Safe working under electrical voltage Up to 1,000 V AC (alternating voltage) Up to 1,500 V DC (direct voltage) Testing carried out by the VDE Testing Institute Tested by the VDE Testing Institute for compliance with the requirements relevant to the certification mark Tools meet the requirements of the German equipment safety law GS = safety certified Tool complies with the German Product Safety Act (ProdSG), as verified by an approved testing and certification body What should I consider when using VDE insulated tools? ⚠️ Inspect VDE tools before every use! VDE insulated tools should always be checked for visible damage to the insulation before use. Cracks, cuts, excessive wear or a visible inner insulation layer indicate that the tool is no longer suitable for working on live electrical systems. If the insulation is damaged, the VDE tool must not be used for live working. ⚠️ VDE tools are no substitute for safe and professional working practices! Even high-quality insulated tools do not automatically make work on electrical installations safe. Appropriate technical qualifications, the correct working methods, suitable personal protective equipment (PPE) and compliance with all applicable safety regulations are equally important. Working on live electrical systems involves particular hazards and must only be carried out by appropriately qualified persons and under the prescribed conditions.
Variants from€8.25*

Variante: GED_GRP_2536_GED2322552
GEDORE EI-1500 CT1-VDE 2170 Check-tool module, empty Simple optical completeness check due to 2-coloured foam inserts, Particularly suitable for work in sensitive areas, where it must be ensured that no tools are left behind, Base layer blue, top layer black. The color blue indicates missing tools, The tool lies slip-proof in its nest and is protected against damage, Recessed grips facilitate the removal of the tool, Clearly visible tool contours make it easier to put the tool back into the correct nest, Resistant against oils and grease, Easy to clean with water, soap and a hand/nail brush, Dimensions: W 157.5 x D 310 mm
Variants from€30.93*



